Standard 325, Edition 7
UL 325

ANSI/CAN/UL Standard for Door, Drapery, Gate, Louver, and Window Operators and Systems

UL Bulletin Edition 7 Published Date: December 05, 2017 Last Revision: February 21, 2023

$398.00-$497.00

Summary of Topics b0325_7_20171205_sum.html

Subject 325

Bulletin Dated: December 5, 2017

SUMMARY OF TOPICS

The following topics were discussed at the meeting of the Standards Technical Panel for Door, Drapery, Gate, Louver, and Window Operators:

1. Constant Pressure Override Capability for Gate Operators Using Portable Wireless Controls

2. Barrier Arm Manual Release Exception

3. Swing Gate Entrapment Zone

4. Remove Maximum 2 Seconds Gate Reversing

5. Class I and II Limiting gate speed

6. Licensing To Purchase Gate Operators

7. Swing Gate Entrapment Zone Definition and Instruction

8. Exception Class I Pedestrian Gate Use

9. Use of Placards on Class I Installations

10. Adding Class IA

11. Addition of Class IS

12. Expansion of Gate Operator Class Types for Installation

13. Require a Usable “Emergency Release,” Not Just a “Means for Manual Operation” for Gate Operators

14. Slide Gate Entrapment Zone - Clarifications

15. Change to Introduction Scope

16. Specific Requirements for Window Operators and Systems

17. Residential Garage Door Operator with Power Supply Cord

18. Removing Type AF and CF Wiring, and Editorial Revision to 15.1.5

19. Propose an Alternate Method for Providing Ground Fault Circuit Interrupter Protection for Convenience Outlets on Appliances

20. Proposal for Button Battery Requirements to be Included in UL 325, Reference to Horizontal Standard, UL 4200A

21. Outdoor Use Clarification of Edge Sensor Testing

22. Requirements for Lasers

23. Limit Upward Force, or Add an External Entrapment Device for Use in the Upward Direction for Commercial Garage Doors

24. Opto Electronic Sensors

25. Unattended Operation Accessory - Light Output

26. Unattended Operation - Alignment of Requirements

27. Battery-Powered Door, Gate, and Window Operators

28. Temperature Test Clarifications

29. Edge Sensor Endurance Test Force Clarification

30. Drapery and Window Blind Operators and Systems

31. Emergency Override Proposals

32. IEC Harmonization

33. UL 5500 - Remote software downloads

Back to Standard 325, Edition 7

The cost to purchase this Standard varies depending on whether you are ordering a hardcopy, PDF or combination of the two. We also offer two different types of subscriptions: a one year and a three year.

You will be able to choose your purchase options on the following pages.

×
×
×
×
×

You have one or more subscriptions that will expire soon.

×

You have one or more licenses to assign

×

Additional information required

To serve you better, please update your account details.

Featured Standards


Recently Published











Coming Soon

UL 48
Electrical Signs
Revision Pages

UL/ULC 25
Meters for Flammable and Combustible Liquids and LP-Gas
Revision Pages

UL 155
Tests for Fire Resistance of Vault and File Room Doors
Revision Pages

UL 310
Electrical Quick-Connect Terminals
New Edition

UL 19
Lined Fire Hose and Hose Assemblies
Revision Pages

UL 104
Elevator Door Locking Devices and Door or Gate Closed Detection Means
New Edition

UL 217
Smoke Alarms
Revision Pages

UL 294
Access Control System Units
Revision Pages
×