SUMMARY OF TOPICS
This revision of ANSI/UL 1286 dated April 21, 2021 is being issued to incorporate the following change:
– Revisions To The Title Of UL 1286 To More Closely Align With The Scope Of the Standard
– Revisions To Cord-Connected System Requirements To Allow For 14 AWG Cord And 15 A Plug Configurations Under Specific Conditions; 11.3.2, 11.3.4, 11.3.5, 38.19
– Revision To The Scope To Clarify That The Requirements Applicable To Individual Commercial Office Furnishings Are Specified in UL 962, Household And Commercial Furnishings; 1.6, 19.10.1, 19.10.2
– Revision To Marking Requirements To Clarify Office Furnishing Type Designation Requirements; 38.20
– Revisions To Construction And Test Requirements Applicable To Raceways To Specify Compliance With UL 5, Surface Metal Raceways And Fittings and UL 5A, Nonmetallic Surface Raceways And Fittings; 3.6, Table 3.1, Section 8, Section 9, 19.12.1.3, Section 23, Section 24, Section 24A, 27.1.2, 35.1.1, 36.1.2, Appendix A
– Addition Of A Definition For An Office Furnishing Unit; 2.19.1, 2.19.2
– Addition Of Electrical Enclosure Requirements; 2.10.2, 3.8 – 3.10
– Revisions To Component Requirements To Clarify That The Standards Listed In Appendix A Are Not All Inclusive; 3.1
– Revisions To And Addition Of Accessory Requirements To Address Trial Installation Of Accessories; 7.9, Section 37A
– Revision To Paragraph 19.7.1 To Allow For Standard European Size Glass Thickness Of 3.0 mm; 19.7.1
– Addition Of Paragraph 19.7.2 To Clarify That The Retention Test Applies To All Types Of Glass For Furnishings Provided With Glass; 19.7.2
– Revision To Paragraph 19.11 And Addition Of Section 34A, Monitor Arms Test, To Clarify The Tests From ANSI/BIFMA X 5.5 That Are To Be Applied In the Evaluation Of Monitor Arms; 19.11.1, 34A.3, 19.12.1.2
– Clarification Of The Spill Test To Include Testing Of A Line-Voltage Outlet Or Low Voltage Outlet Such As A USB Port; 30.1.2
– Revisions To Section 33, Functional And Proof Load Tests, To Clarify The Required Tests From ANSI/BIFMA X 5.6 That Are To Be Applied In The Evaluation Of Furnishings; 33.1.1, 33.1.2, 33.2, 33.3, Table 33.1, Table 33.2, Table 33.3
– Revision To The Glass Panel Test ─ Retention To Specify The Correct Metric Unit Of Impact For The Test; 35.2.2
– Addition To Installation And Operating Instruction Requirements To Specify System Components Evaluated As Part Of The Complete Furnishing; 39.10
– Revisions To Supplement SA, Modular Pre-Wired Office Furnishing Floor Raceway Systems, To Remove Duplicative Requirements; 2.32, SA2.3 – SA2.5, SA2.8, SA2.9, Section SA5, Section SA9, Section SA10, SA16.1, Section SA27, Section SA29
– Revisions To Section 19.9, Flammability Of Materials To Clarify The Requirement; 19.9.1 – 19.9.4
– Revisions And Additions To Supplement SA, Modular Pre-Wired Office Furnishing Floor Raceway Systems To Allow For Under Carpet Applications; 1.3, SA2.7, SA3.2.1, SA4.1, SA4.3, SA4.5, SA4.6, SA26.1, SA33.1, SA35.7 – SA35.10
– Editorial Updates; SA16.2