Standard 1598, Edition 3
UL 1598
SUPERSEDED

Luminaires

UL CSDS Proposal Published Date: August 28, 2015 Last Revision: October 17, 2012

$0.00

Summary of Topics b1598_3_20150828_sum.html

Subject 1598

Bulletin Dated: August 28, 2015

SUMMARY OF TOPICS

The following changes in requirements to the Standard for Luminaires, UL 1598, are being proposed for preliminary review and comment only:

1. For Preliminary Review Only: Add requirements for use of Schedule 40 or Schedule 80 rigid PVC conduit as luminaire pole and electrical enclosure

2. For Preliminary Review Only: Revise requirements for combination HID/incandescent lamp replacement marking for remote ballasted HID luminaires

3. For Preliminary Review Only: Revise requirements for Rain and Sprinkler Test Methods

4. For Preliminary Review Only: Revise spacings requirements applied between component printed circuit boards and luminaire dead metal

5. For Preliminary Review Only: Add requirements for luminaires for use in clothes closets in Clause 12.7 (USA)

6. For Preliminary Review Only: Revise requirements for dielectric testing of LED luminaires

7. For Preliminary Review Only: Addition of dielectric voltage-withstand exception to factory production test

8. For Preliminary Review Only: Revise requirements for self-threading screw torque

9. For Preliminary Review Only: Add paragraph 1.3 to reference UL 8750 for requirements for LED components and subassemblies

10. For Preliminary Review Only: Add standard references to Clause 2

11. For Preliminary Review Only: Revise polymeric material requirements for LED optics

12. For Preliminary Review Only: Clarify requirements for luminaires using lampholders having cellulosic fiber husks

13. For Preliminary Review Only: Clarify requirements for the use of flexible cord for power supply connections

14. Clarify requirements for the use of flexible cord and attachment plugs for connecting luminaires to the branch circuit

15. For Preliminary Review Only: Add requirements for recessed luminaires for installation in air-handling spaces

16. For Preliminary Review Only: Add supplementary requirements for LED luminaires

17. For Preliminary Review Only: Revise electrical spacings to include USA requirement for printed wiring board

18. For Preliminary Review Only: Revise enclosure requirements

19. For Preliminary Review Only: Add standard references to Annex A

20. For Preliminary Review Only: Add requirements for LED Type Non-IC inherently protected recessed luminaires

21. For Preliminary Review Only: Revise requirements for thermal protection for LED recessed luminaires

22. For Preliminary Review Only: Add requirements for mechanical joints and fastenings

23. For Preliminary Review Only: Revise existing definitions and add new definitions

24. For Preliminary Review Only: Revise flammability requirements for an LED lens and diffuser

25. For Preliminary Review Only: Add spacings options for UL 1598 using requirements from UL 840

26. For Preliminary Review Only: Add requirements for luminaires for use in clothes closets in Clause 12.8 (CAN) (Please note similarities with the USA proposal Topic 5)

27. For Preliminary Review Only: Add new Section 11.1.5 (CAN) for polymeric light diffusers and lenses compliance with the National Building Code of Canada

28. For Preliminary Review Only: Revise font size requirements for product labels

29. For Preliminary Review Only: Revise definition of User Maintenance

30. For Preliminary Review Only: Revise requirement in part (c) of Clause 10.6.9 (CAN) to include wall-mounted luminaires

31. For Preliminary Review Only: Revision of factory production tests, dielectric voltage-withstand

Back to Standard 1598, Edition 3

The cost to purchase this Standard varies depending on whether you are ordering a hardcopy, PDF or combination of the two. We also offer two different types of subscriptions: a one year and a three year.

You will be able to choose your purchase options on the following pages.

×
×
×
×
×

You have one or more subscriptions that will expire soon.

×

You have one or more licenses to assign

×

Additional information required

To serve you better, please update your account details.

Featured Standards


Recently Published











Coming Soon

UL 48
Electrical Signs
Revision Pages

UL/ULC 25
Meters for Flammable and Combustible Liquids and LP-Gas
Revision Pages

UL 155
Tests for Fire Resistance of Vault and File Room Doors
Revision Pages

UL 310
Electrical Quick-Connect Terminals
New Edition

UL 19
Lined Fire Hose and Hose Assemblies
Revision Pages

UL 104
Elevator Door Locking Devices and Door or Gate Closed Detection Means
New Edition

UL 217
Smoke Alarms
Revision Pages

UL 294
Access Control System Units
Revision Pages
×

Email Verification Required

To enhance security and protect our community from fraudulent activity, we require email address confirmation before orders can be placed. This step ensures that all orders come from verified sources, helping us maintain a safe and trusted environment for everyone. Thank you for your cooperation.

To resend the confirmation email please click here. The confirmation email will look like the sample below.

Sample

example email
×