Standard 9540, Edition 2
UL 9540

Standard for Energy Storage Systems and Equipment

UL CSDS Proposal Edition 2 Published Date: October 18, 2019 Last Revision: April 09, 2021

$0.00

Summary of Topics b9540_2_20191018_sum.html

Subject 9540

Bulletin Dated: October 18, 2019

SUMMARY OF TOPICS

The following topics for the Standard for Energy Storage Systems and Equipment, UL 9540, are being recirculated:

1. The proposed second edition of ANSI/CAN/UL 9540 with the following changes: (a) Addition of UL 1973 to Appendix A Component List, (b) Addition of ISO Functional safety standards, (c) Revision of grounding and bonding system construction, (d) Revision of the strength of enclosure walls and supports requirements, (e) References to required signage and instructions, (f) Deletion of non-mandatory language throughout standard, (g) Revision of scope language for clarity, (h) Revisions to the Fire Detection and Suppression Section, (i) Proposed addition of new 32.4.6, (j) Revision to Mechanical Tests for Clarification, (k) Clarification of 1.2, (l) Revision of 6.4, harmonization with other existing standards, (m) Enclosure materials for outdoor installations, (n) Short Circuit Exposure Evaluation, (o) Clarification of Scope, (p) Clarifications of Component and Normative Reference Section, (q) Clarification of corrosion requirements for Enclosures, (r) Revisions to make the use of term “energy storage system” consistent throughout entire standard, (s) Clarification of Instructions for Worker Safety, (t) Revisions to Clarify Intent and Application of 11.1 and 12.2, (u) Clarifications of system requirements for where the system is installed, (v) Clarification of the Intended Environment, (w) Clarification of Bonding and Grounding Requirements, (x) Clarifications of 17.1 and 18.1, (y) Clarification of 21.1, (z) Clarification of 32.2.2, (aa) Clarification of 40.4 and 40.5, (ab) Clarification of 11.2, (ac) Addition of requirements for Residential ESS, (ad) Addition of production checks on electronic controls, (ae) Addition of requirements for Quality Control of production, (af) Additional testing options, (ag) Addition of a wall mount fixture test for wall mounted ESS, (ah) Addition of Normative Appendix D for alternative lead acid or ni-cad battery system evaluation, (ai) Revision of 12.3 to add short circuit protection, (aj) Addition of Informative Appendix E for Guidance on Capacity and Separation Distance Limits for ESS, (ak) Addition of EMC testing, (al) Revision of utility grid interaction reaction requirements, (am) Clarification of the scope, (an) Clarification of Vapor concentration requirements, (ao) Addition of emergency contact marking, (ap) Clarification of flame test surface area; aq) Addition of 8.2 and Appendix F

2. Revisions for electrochemical ESS above 20 kWh.

Back to Standard 9540, Edition 2

The cost to purchase this Standard varies depending on whether you are ordering a hardcopy, PDF or combination of the two. We also offer two different types of subscriptions: a one year and a three year.

You will be able to choose your purchase options on the following pages.

×
×
×
×
×

You have one or more subscriptions that will expire soon.

×

You have one or more licenses to assign

×

Additional information required

To serve you better, please update your account details.

Featured Standards


Recently Published











Coming Soon

UL 48
Electrical Signs
Revision Pages

UL/ULC 25
Meters for Flammable and Combustible Liquids and LP-Gas
Revision Pages

UL 155
Tests for Fire Resistance of Vault and File Room Doors
Revision Pages

UL 310
Electrical Quick-Connect Terminals
New Edition

UL 19
Lined Fire Hose and Hose Assemblies
Revision Pages

UL 104
Elevator Door Locking Devices and Door or Gate Closed Detection Means
New Edition

UL 217
Smoke Alarms
Revision Pages

UL 294
Access Control System Units
Revision Pages
×