013700-000000-0000001 Scope
1.1 These requirements apply to factory-built unvented decorative appliances, that burn liquid or gelled alcohol-based fuels, and are intended to be fixed, non-moveable appliances, including only the following:
- a) Floor-mounted appliances; 
- b) Wall-mounted appliances; 
- c) Free-standing appliances; 
- d) Fireplace grates installed in existing masonry fireplaces, and rated below 40,000 Btu/h (11.7 kW) output; and 
- e) Appliance combustion chambers installed into site-built enclosures. 
1.2 These appliances are intended to be decorative in nature and not intended to be utilized as a primary heat source. These appliances are limited to a maximum fuel input rate of 0.25 US gal/h (0.95 L/h).
1.3 Floor-mounted, wall-mounted and free-standing appliances include an integral enclosure, fire chamber and fuel reservoir, or combination unit, and provision for refueling. 
1.4 These appliances are not intended for:
- a) Use with fuel oils, kerosene, gasoline, and other non-alcohols; 
- b) Use in spaces in which flammable vapors or gases may be present; 
- c) Use as cooking appliances; 
- d) Use in conjunction with blower assemblies; 
- e) Installation in a bathroom; or 
- f) Installation in a room where sleeping accommodation is provided. 
1.5 These appliances are intended for installation in occupancies where use is permitted by local codes, such as:
- a) In the United States:  - 1) NFPA 1, Uniform Fire Code; 
- 2) NFPA 101, Life Safety Code; 
- 3) Other applicable federal and state regulations. 
 
- b) In Canada: - 1) The National Building Code of Canada; and 
- 2) The National Fire Code of Canada; 
- 3) Regulation of the authority having jurisdiction.