Standard 541, Edition 6
UL 541
SUPERSEDED

Standard for Refrigerated Vending Machines

UL CSDS Proposal
Published Date: September 25, 2009
Last Revision: October 23, 2009

$0.00

Summary of Topics b0541_6_20090925_sum.html

Subject 541

Bulletin Dated: September 25, 2009

SUMMARY OF TOPICS

The following changes in requirements to the Standard for Refrigerated Vending Machines, UL 541, are being proposed:

1. Proposed Addition Of Paragraph 3.6.1 To Define The Term Motor Controller And Proposed Revision To Paragraph 22.1.2 To Delete The Description Of A Motor Controller

2. Proposed Revision To Paragraph 3.10 To Clarify The Definition Of A Vendor Or Refrigerated Vending Machine That Aligns With Recent Changes To The National Electrical Code

3. Proposed Revision To Paragraph 8.3.3.1 To Delete Reference To The Obsolete Cord Type Of "W-A"

4. Proposed Revision To Paragraphs 15.2.1, 53.1.5, 53.4.1, 63.6 And Proposed Deletion Of Paragraph 63.7 To Delete The Reference To HACR Type Circuit Breakers

5. Proposed Revisions To Section 21 And Proposed Addition Of Section 21A To Separate General Motor Requirements From Overload Protection Requirements, And Proposed Addition Of A New Requirement To Require That Protective Electronic Circuits Used In Motors Comply With UL 991, Tests For Safety-Related Controls Employing Solid-State Devices Or UL 60730-1A, Automatic Electrical Controls For Household And Similar Use, Part 1

6. Proposed Addition Of Paragraph 22.1.14 To Require That A Temperature Control For A Motor-Compressor Comply With Tests In UL 873, Temperature-Indicating And Regulating Equipment

7. Proposed Addition Of A New Paragraph 24.1 To Specify That An Electrically Operated Value Or Solenoid Shall Comply With UL 429, Electrically-Operated Valves

8. Proposed Revision To Paragraph 31.1 To Require That A Pressure-Limiting Device Comply With Tests In UL 873, Temperature-Indicating And Regulating Equipment

9. Proposed Revision To The Leakage Current Test Requirements In Paragraphs 34.1 And 34.6 To Provide An Option For Vending Machines To Comply With The Leakage Current Requirements In UL 101, Leakage Current For Appliances, And To Clarify Humidity Conditions For The Test

10. Proposed Revision To Paragraph 37.1 To Allow For The Use Of A Direct Potential To Test Vending Machines To The Dielectric Voltage-Withstand Test

11. Proposed Revisions To Paragraph 43.1 To Clarify The Compliance Criteria For The Stability Test

12. Proposed Revisions To Paragraph 55.2 To Specify That Refrigerant-Containing Components That Comply With UL 207, Refrigerant-Containing Components And Accessories, Nonelectrical May Be Used Without Additional Testing

13. Proposed Revision To Paragraph 62.1 To Clarify That Permanent Markings Shall Comply With Section 58 Of UL 541 Or With UL 969, Marking And Labeling Systems

14. Proposed Revision To Paragraph 61.2.1 To Allow The Production Line Dielectric Voltage Withstand Test To Be Conducted Pior To The Attachment Of The Power Supply Cord

15. Proposed Editorial Revisions To Address Use Of Consistent Terminology, Delete Dates Associated With Referenced Standards, Correct References, And Other Editorial Changes

Revisions and Related Documents

Revisions
Red Line Std. (12)

Date      
October 23, 2009 Revision
February 24, 2006 Revision
October 10, 2005 Revision
October 22, 2004 Revision
October 30, 2003 Revision
October 03, 2003 Revision
October 16, 2001 Revision
February 26, 1998 Revision
November 06, 1997 Revision
April 21, 1997 Revision
August 08, 1996 Revision
May 03, 1996 Revision
Showing 10 of XX
Show All

CSDS
Proposals (5)

CSDS Proposal   

CSDS Proposals

An electronic document associated with a UL Standard for Safety or Outline of Investigation, and issued by UL to propose:

  • A revision of a single or multiple requirement(s).
  • A complete new edition of an existing Standard or Outline.
  • A new Standard or Outline that has not previously been published.

CSDS Proposals provide access to view the proposal and submit comments within UL's Collaborative Standards Development System (CSDS) appropriately.

×

September 25, 2009
July 09, 2009
May 06, 2005
December 25, 2004
December 03, 2004
Showing 10 of XX
Show All

UL LLC CRD (0)

Showing 10 of XX
Show All None available.
Showing 10 of XX
Show All

Other Updates (6)

Showing 10 of XX
Show All
Bulletin   

Bulletins

These bulletins are not used in CSDS. These are announcement and report type bulletins.

×
Summary of Topics (SOT)
August 27, 2004 View
July 28, 2003 View
May 07, 2003 View
October 18, 2002 View
May 18, 2001 N/A
January 09, 1997 N/A
Showing 10 of XX
Show All
Showing 10 of XX
Show All
Showing 10 of XX
Show All
Showing 10 of XX
Show All
Showing 10 of XX
Show All

Referenced Standards (0)

Showing 10 of XX
Show AllNone available.

Reverse Referenced Standards (1)

UL 541 is referenced in the following list of UL Standards

StandardEditionTitle
751 9 Vending Machines
Showing 10 of XX
Show All

The cost to purchase this Standard varies depending on whether you are ordering a hardcopy, PDF or combination of the two. We also offer two different types of subscriptions: a one year and a three year.

You will be able to choose your purchase options on the following pages.

×

The ULSE standard development process is under continuous maintenance, which means new work may already be in progress when a revision is published.

×
×
×
×
×

You have one or more subscriptions that will expire soon.

×

You have one or more licenses to assign

×

Additional information required

To serve you better, please update your account details.

Featured Standards


Recently Published











Coming Soon

UL 48
Electrical Signs
Revision Pages

UL/ULC 25
Meters for Flammable and Combustible Liquids and LP-Gas
Revision Pages

UL 155
Tests for Fire Resistance of Vault and File Room Doors
Revision Pages

UL 310
Electrical Quick-Connect Terminals
New Edition

UL 19
Lined Fire Hose and Hose Assemblies
Revision Pages

UL 104
Elevator Door Locking Devices and Door or Gate Closed Detection Means
New Edition

UL 217
Smoke Alarms
Revision Pages

UL 294
Access Control System Units
Revision Pages
×

Email Verification Required

To enhance security and protect our community from fraudulent activity, we require email address confirmation before orders can be placed. This step ensures that all orders come from verified sources, helping us maintain a safe and trusted environment for everyone. Thank you for your cooperation.

To resend the confirmation email please click here. The confirmation email will look like the sample below.

Sample

example email
×